3516C Tier 4 Final

3516C Tier 4 Final

The 3516C HD generator set has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The engines ...
PDF Print Share

Generator Set Specifications

Standby Rating
2500/2000 ekW
Prime Power Rating
1825/2250 ekW
Emissions/Fuel Strategy
U.S. EPA Certified
Voltage
480 to 13800 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Mission Critical, Prime
Maximum Rating
2500 ekW
Minimum Rating
1825 ekW

Engine Specifications

Engine Model
3516C HD, ATAAC, V-16, 4-Stroke Water-Cooled Diesel
Bore
6.69in
Stroke
8.46in
Displacement
78in
Compression Ratio
14.7:1
Aspiration
TA
Fuel System
Electronic unit injection
Governor Type
ADEM™A4

Generator Set Dimensions

Length - Minimum
267.6in
Length - Maximum
277in
Width - Minimum
93.7in
Width - Maximum
101.2in
Height - Minimum
116.7in
Height - Maximum
118.9in
Dry Weight - Genset (minimum)
37200lb
Dry Weight - Genset (maximum)
40280lb

Standard Equipment:

Optional Equipment:

    Control System
    • EMCP 4.4
    Air Inlet System
    • Single element filter
    • Dual element air cleaner
    Exhaust
    • Exhaust mufflers
    Generator
    • Internal excitation (IE)
    • Anti-condensation heater
    • Oversize and premium generators
    • Permanent magnet excitation (PMG)
    Cooling System
    • Coolant
    • Water level switch gauges
    • Standard ambient radiators
    • Optional installed ATAAC radiators
    • Optional installed radiators
    • Standard ambient ATAAC radiators
    Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
    Crankcase System
    • No explosion relief valves
    • Explosion relief valves
    • Ventilation system
    Control Panels
    • Remote monitoring software
    • Digital I/O module
    • Generator temperature monitoring & protection
    • Load share module
    Exhaust System
    • Tier 4 clean emissions module
    • Flexible fittings
    • Flanges
    • Tier 4 clean emission MOD Kits
    • Mufflers
    • Tier 4 dosing cabinet
    • Flange and exhaust expanders
    • Clean emission parts
    • Exhaust offset
    • Y Adapters
    • Elbows
    Mounting
    • IBC isolators
    Starting/charging
    • Battery chargers
    • Heavy duty starting system
    • Charging alternator
    • Air starting motor with control and silencer
    • Oversize batteries
    Fuel System
    • Primary fuel filter
    • Fuel priming pumps (Tier 4) - Manual or electric
    General
    • Automatic transfer switches (ATS)
    • The following options are based on regional and product configuration:
    • EEC Declaration of Conformity
    • Enclosures: Sound attenuated, weather protective
    • UL 2200 package
    • US aid emblem
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • EU Certificate of Conformance (CE)
    • Integral & sub-base UL listed dual wall fuel tanks
    • CSA Certification
    • Special paint (Colors other than Caterpillar yellow or high performance paints)
    • Integral & sub-base fuel tanks
    Generators And Attachments
    • Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
    • Generator conversion
    • Thermostat for space heater
    • Alternator air cleaner
    • Differential current transformers (DCT) 8.7 kV and 15 kV classes
    • Space heater kit
    • High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
    • High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
    • Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
    Instrumentation
    • Pyrometer and thermocouples
    Lubrication System
    • Lube oil in standard sump
    • Prelube pumps
    • Oil level regulator
    Mounting System
    • IBC vibration isolators
    • Spring type vibration isolators
    • Puck style low efficiency isolators
    Power Connections
    • Ground cables between generator and terminal box
    • Right side power connections
    • 2700 Frame, four lead, four terminal
    • Neutral ground connections
    • Center post busbars
    • Rear power connections
    • Left side power connections
    • Low voltage Circuit breakers
    Special Tests / Reports
    • PGS Test report @ 1.0 power factor
    • IBC Certification
    • Canadian Standards Association certification
    • PGS Test report @ 0.8 power factor
    • Generator set fuel consumption test
    • Generator test report
    • Torsional vibration analysis reports
    • Standard engine test charge
    • OSHPD Certification
    • Fuel consumption test
    Starting And Charging
    • Jacket water heaters
    • Electric starting motors
    • Air starting motors
    • 10, 20, 35 and 50 Amp Battery chargers
    • Air pressure regulator
    • 24 Volt battery set - Dry
    • Engine barring device
    • Starter cover
    Extended Service Coverage
    • Platinum, Gold and Silver coverage