C3.3 Generator Set

C3.3 Generator Set

360° Exterior View

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

PDF Print Share

Generator Set Specifications

Maximum Rating
60.0 ekW
Minimum Rating
27.0 ekW
Emissions/Fuel Strategy
EU Stage II & R96/EUIIIa
Voltage
110 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Prime

Engine Specifications

Engine Model
Cat® C3.3
Bore
4.1in
Stroke
5in
Displacement
201.4in³
Compression Ratio
17.25:1, 19.25:1
Aspiration
Turbocharged
Fuel System
Direct Injection
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
43.9in
Width - Maximum
38.2in
Height - Maximum
53.6in

Standard Equipment:

Optional Equipment:

    Alternator System
    • LC Frame alternator
    • Anti-condensation heater
    • Permanent magnet excitation (PMG)
    • LC Frame alternator with coastal protection
    • R Frame auxilliary winding
    Alternator
    • Alternator removal options
    Circuit Breakers
    • 4 Pole Circuit breaker to 250A
    • Padlockable breaker device
    Control Panels
    • GCCP 1.3
    Control Panel Options
    • Overload shutdown via breaker
    • Volt free contacts
    • Earth leakage (2 wire only)
    • Speed adjust potentiometer
    • Voltage adjust potentiometer
    • Battery charger
    • Control panel heater
    • Earth fault (2 wire only)
    • Panel mounted audible alarm
    • Emergency stop with key
    Cooling System
    • Coolant heater
    • Low coolant level shutdown
    • Low coolant temperature alarm
    Certifications
    • European upgrade to STD set for "CE"
    • Global certification for CIS
    Enclosures
    • CEE for sockets for enclosure
    • Socket blanking plate
    • Sound attenuated level 1 enclosure (GALV)
    • Sound attenuated level 2 enclosure CE
    • Rental pack (CAE only)
    Fuel System
    • Skidbase for CALG enclosure sets
    • Low fuel level shutdown
    • High fuel level alarm
    • Compact skidbase for open sets
    • Low fuel level alarm
    • Bunded fuel tank
    • Open set narrow tankbase
    Mounting Options
    • Silencer installation kit
    • Battery removal
    • Electronic governor
    • Residential silencer
    • External single point lift - enclosure
    Special Packing Inspections
    • PGS Test report @ 0.8 power factor
    • PGS Test report @ 1.0 power factor
    General
    • Stone guards/rad trans flange
    • Packing case - compact set
    • Packing case - canopied set