Generator Set Specifications

Minimum Rating
282 ekW
Maximum Rating
940 ekW
Frequency
60hz

Engine Specifications

Configuration
Vee-12, 4-stroke-Cycle-Diesel
Aspiration
Turbocharged-aftercooled aspiration
Bore
5.71in
Stroke
6.38in
Displacement
1959in³
Emissions
U.S. EPA Tier 4 Final certified / IMO III emissions certified (SCR required)
Rated Engine Speed
1800 rpm
Governor
Electronic (A5 ECM)
Generator
SR5 - Form Wound
Cooling
Heat exchanger, keel or radiator cooled
Oil Change Interval
750 hrs
Refill Capacity
Lube Oil System w/ oil filter change: 146 L (38.5 gal)

Generator Set Dimensions

Length
167.2 in/4245 mm (minimum), 226.1 in/5742 mm (maximum)
Width
59.9 in/1521 mm (minimum), 89.8 in/2280 mm (maximum)
Height
70.4 in/1747 mm (minimum), 92.8 in/2356 mm (maximum)
Engine Dry Weight
15721 lb/7131 kg (minimum), 21998 lb/9978 kg (maximum)

Clean Emissions Module (CEM) - Dimensions

6 Brick Z-Flow - Length
147.7in
Dosing Cabinet - Weight
209lb
6 Brick Z-Flow - Weight
1246lb
6 Brick U-Flow - Weight
1235lb
Dosing Cabinet - Height
22.8in
6 Brick U-Flow - Width
56.9in
6 Brick U-Flow - Length
85in
Dosing Cabinet - Width
18.8in
6 Brick Z-Flow - Width
43.5in
6 Brick U-Flow - Height
23.5in
Dosing Cabinet - Length
37.4in
6 Brick Z-Flow - Height
23.5in

Emissions

Utilizes SCR Technology to enable U.S. EPA Tier 4 Final and IMO III emission regulations compliance while lowering operational costs

Control Strategy

Utilizes closed loop air assisted DEF dosing control strategy that delivers: Highest efficiency mixing and control to lower operational costs ; Extends emissions useful life ; Ensures compliance ; Flexible to urea quality

Fuel System

Enhanced control of fuel injection optimized through crank timing and the A5 ECM technology

Power Reserve

Industry leading power reserve

Certifications

Wide range of available Marine Society certifications

Warranty

Industry-leading warranty coverage for factory packaged components

Service

Global dealer network for service in any location

Standard Equipment:

Optional Equipment:

    Alarm And Protection
    • MGCP III B control panel with Cat® Alarm and Protection System
    • IP44 generator protection
    Exhaust System
    • Muffler
    • Water-in-fuel and exhaust temperature sensors
    • SOLAS approved spray shielding
    Charging System
    • Charging alternator
    Fuel System
    • Manual or electric fuel priming pump
    • Fuel cooler
    Lube System
    • Duplex oil filters
    Starting System
    • Starting motors – air, electric or redundant